Watlow's WATROD tubular heater elements and flat FIREBAR elements are designed primarily for direct immersion in liquids such as water, oils, solvents and process solutions, molten materials as well as air and gases. By generating all the heat within the liquid or process, these heaters are virtually 100 percent energy efficient. These versatile heaters can also be formed and shaped into various geometries for radiant heating and contact surface heating applications. UL® and CSA component recognized elements available.
| Products | Available Sheath Diameters | Sheath Materials | Maximum Sheath Temperature | Typical Maximum Watt Densities* | |
|---|---|---|---|---|---|
| mm | in. | ||||
| WATROD Tubular® | 6.6, 8.0, 9.5, 10.9, 12.0, 12.4, 15.9 |
0.260, 0.315, 0.375, 0.430, 0.475, 0.490, 0.625 | Inconel® | To 871°C (1600°F) | To 18.6 W/cm² (120 W/in²), dependent on the sheath material, watt density and heater application |
| Incoloy® | To 871°C (1600°F) | ||||
| 304SS | To 650°C (1200°F) | ||||
| 316SS | To 871°C (1600°F) | ||||
| Steel | To 400°C (750°F) | ||||
| Copper | To 175°C (350°F) | ||||
| Single-Ended Tubular | 9.5, 10.9, 12.0, 12.4, 15.9 | 0.375, 0.430, 0.475, 0.490, 0.625 | Incoloy® | 650°C (1200°F) | To 7 W/cm² (45 W/in² |
| 304SS | |||||
| High Temperature WATROD | 9.5 and 10.9 | 0.375 and 0.430 | Inconel® 600 | To 980°C (1800°F) | To 4.7 W/cm² (30 W/in²) |
| MULTICOIL | 12.0 and 12.4 | 0.475 and 4.90 | Inconel® | To 871°C (1600°F) | To 18.6 W/cm² (120 W/in²), dependent on the sheath material, watt density and heater application |
| Incoloy® | To 871°C (1600°F) | ||||
| 304SS | To 650°C (1200°F) | ||||
| 316SS | To 871°C (1600°F) | ||||
| Steel | To 400°C (750°F) | ||||
| Copper | To 175°C (350°F) | ||||
| FIREBAR Flat Tubular | 5/8 in.: 5.9 x 16.5 |
0.235 x 0.650 |
Incoloy® | 760°C (1400°F) | To 14 W/cm² (90 W/in² |
| 304SS | 650°C (1200°F) | ||||
| 1 in.: 5.9 x 25.7 |
0.235 x 1.010 |
Incoloy® | 760°C (1400°F) | ||
| 304SS | 650°C (1200°F) |
||||
Click on the below links for more product information. PDF documents require Adobe® Reader® version 7 or higher for viewing.
| Related News Releases and Newsletters | Date |
|---|---|
| Interference Fit Construction Heaters from Watlow® Improve ... | 15-Jul-2008 |
| Watlow Opens a New Manufacturing Facility in Shanghai, China | 06-Nov-2006 |
| Watlow's FIREBAR Flat Tubular Heater Proves its Superiority Over Round ... | 13-Jun-2006 |
| Watlow Introduces RAPID SHIP Program for Standard Tubular Heaters | 19-Apr-2006 |
| Watts Current - Volume Twenty-Seven, First Quarter, 2002 | 21-Mar-2002 |
| Watts Current - Volume Twenty-Two, Second Quarter, 2000 | 01-Apr-2000 |
| Watts Current - Volume Twenty, Third Quarter, 1999 | 03-Jul-1999 |
| Watts Current - Volume Eighteen, First Quarter 1999 | 01-Jan-1999 |
| Related Technical Documents | Size/Pages |
|---|---|
| FIREBAR Flange Heater Installation & Maintenance Manual | 61K / 7 (PDF) |
| FIREBAR Screw Plug Installation & Maintenance Manual | 59K / 7 (PDF) |
| Humidity Conditioning Requirements of Commercial Electric Cooking Appliances ... | 26K / 1 (PDF) |
| ISO 9001:2000 Certification - Hannibal | 130K / 1 (PDF) |
| Thermostat Control Installation & Maintenance Manual | 83K / 6 (PDF) |
| WATROD & FIREROD Installation & Maintenance Manual | 49K / 5 (PDF) |
| WATROD Circulation Heater Installation & Maintenance Manual | 65K / 7 (PDF) |
| WATROD Duct Heater (Module Only) Installation & Maintenance Manual | 93K / 8 (PDF) |
| WATROD Duct Heater Installation & Maintenance Manual | 171K / 12 (PDF) |
| WATROD Flange Heater Installation & Maintenance Manual | 58K / 7 (PDF) |
| WATROD Modular Duct Heater Installation & Maintenance Manual | 94K / 8 (PDF) |
| WATROD Over-the-Side Installation & Maintenance Manual | 54K / 6 (PDF) |
| WATROD Screw Plug Installation & Maintenance Manual | 57K / 6 (PDF) |